Título : | Análisis microscópico y macroscópico in vitro de materiales de restauración en piezas dentales sometidas a altas temperaturas con fines forenses |
Autor : | Moya Silva, Tamara Jacqueline Machado Guerra, Christian Santiago |
Palabras clave : | ODONTOLOGÍA FORENSE RESINAS COMPUESTAS |
Fecha de publicación : | 2017 |
Editorial : | Quito: UCE |
Citación : | Machado Guerra, Christian Santiago (2017).Análisis microscópico y macroscópico in vitro de materiales de restauración en piezas dentales sometidas a altas temperaturas con fines forenses. Trabajo de titulación previo a la obtención del Título de Odontólogo. Carrera de Odontología. Quito: UCE. 171 p. |
Resumen : | Objetivo: Describir y comparar el comportamiento de las resinas compuestas nano-hibridas, y una resina micro-hibrida, sometidas a temperaturas elevadas (600-800 °C), macroscópica y microscópicamente, con el fin de encontrar características distintivas de cada una, para así establecer patrones de identificación forense Metodología: Se utilizaron sesenta terceros molares sanos, divididas en tres grupos A, B y C se realizaron cavidades clase I oclusales, para el grupo A se utilizó la resina nano-hibrida, grupo B nano-hibrida, grupo C micro-hibrida. Las muestras fueron sometidas a 600°C y 800°C en un horno tipo mufla, posteriormente fotografiadas con una cámara Nikon 3300 con un lente de aumento de 18,55 mm, se observó en el Estereomicroscópio Marca Nikon SMZ-100para luego ser medidas sus variables a través del software AutoCAD 2018 y para el análisis de color se creó una base de datos con IDE para ser ejecutada en JAVA. Resultados: obtuvimos resultados similares entre dos tipos de resinas de un sistema nano- Hibrido y diferentes en el sistema micro-hibrido al ser sometidos a 600° y 800°C.Conclusiones: De acuerdo a la composición en la matriz orgánica y el tamaño de las partículas de relleno obtuvimos las características distintivas de cada uno de los tres sistemas comerciales estudiados, la información in-vitro obtenida en la presente investigación será de gran utilidad para el cotejo ante y post-mortem con fines forenses Objective: to describe and compare the behavior of nano-hybrid compound resins and a micro-hybrid resin, subjected to high temperatures (600-800°C), in a macroscopic and microscopic level, in order to find the differences between them and then establish patterns for forensic identification. Methodology: there were used sixty healthy molars divided into three groups: A, B and C. There were made type I occlusal perforations. Group A received nano-hybrid resin. Group B used nano-hybrid and Group C micro-hybrid. The samples were subjected to temperatures 600°C and 800°C in a muffle furnace. They were later photographed with a Nikon 3300 camera with a lens of 18,55 mm. It was observed in the Stereomicroscope of the brand Nikon SMZ-100 to then measure the variables through the software AutoCAD 2018. For the analysis of the color it was created a data base with IDE to be executed in JAVA. Results: we obtained similar results between two types of resins in a nano hybrid system and different results in the micro-hybrid system, when subjected to 600° and 800°C.Conclusions: according to the composition in the organic matrix and the size of the filling particles there were obtained distinctive characteristics in each one of the three commercial systems studied. The in vitro information obtained in this information will be very useful to compare ante and post mortem with forensic purposes |
URI : | http://www.dspace.uce.edu.ec/handle/25000/13910 |
Aparece en las colecciones: | Titulación - Odontología |